UltraLift SD Compact Training FAQ
Maschinengrundlagen
Q: What is the principle of HIFU?
A:
HIFU (Hochintensiver fokussierter Ultraschall) uses focused ultrasound energy to heat precise depths of tissue beneath the skin’s surface. It is a non-invasive cosmetic treatment that uses ultrasound energy to stimulate the deep layers of the skin, Förderung der Kollagenproduktion und dadurch Straffung, gestraffte Haut. Es wird häufig zur Gesichtsstraffung und Körperkonturierung verwendet.
Q: What is the main benifits of the UltraLift SD Compact HIFU?
A: Ultra SD employs Micro-Focused Ultrasound (VERLUST), representing an advanced iteration of HIFU technology. Key technical benefits include:
Enhanced targeting accuracy: Smaller focal zones allow precise energy delivery to targeted tissue layers.
Optimized patient comfort: Improved emission modulation ensures a more tolerable treatment experience.
Superior clinical outcomes: High precision enhances lifting and tightening efficacy.
Dual-modality synergy: Integrates HIFU with RF (Radiofrequenz), compatible with sensitive skin types.
Ergonomically designed handpiece: Lightweight and balanced for reduced operator fatigue and improved handling.
Q: What is the main function of the UltraLift SD Compact HIFU?
A: The UltraLift SD Compact is designed for non-invasive face lifting, Faltenreduktion, und Körperformung. It targets multiple skin layers to achieve long-lasting tightening without downtime.
Q: When was the UltraLift SD Compact HIFU system launched?
A: The UltraLift SD system was launched in 2021 as an advanced version of traditional HIFU devices, offering improved precision and comfort.
Q: What are the differences between Ultra SD and traditional HIFU devices?
A:
Compared with traditional HIFU:
More stable output for consistent results
More stable output for consistent results
Smaller, tragbares Design (Compact version)
Enhanced cooling system for cartridge durability
Smart screen interface with pre-set modes
Upgraded SD cartridges that last longer and provide more precise energy distribution
Handstück & Patronen
Q: What do the cartridge depths (1.5mm, 3.0mm, 4.5mm) signify?
A: They represent the tissue penetration depth of ultrasound energy:
1.5mm: Epidermal layer
3.0mm: Dermal layer
4.5mm: SMAS (superficial musculoaponeurotic system) Schicht
Q: What is the purpose of the cartridge stickers?
A: The stickers seal the water inlet. Water acts as a coupling medium for efficient ultrasound energy transmission.
Q: How can I tell when water needs refilling?
A: Each cartridge features a visible water level indicator. Refill when the level drops below the recommended threshold.
Q: How many handpieces are supplied per order?
A: Each system comes with 7 handpieceS as standard. Additional handpieces can be purchased separately.
Missing items should be reported to support with a video for prompt resolution.
Q: What is the purpose of the 9mm cartridge?
A:
Der 9mm cartridge is ideal for Körperstraffung in areas like the abdomen, Waffen, Schenkel, and flanks. It reduces localized fat and improves skin firmness.
Q: Can 1.5mm, 3.0mm, and 4.5mm cartridges be used on the body?
A:
They are primarily designed for the Gesicht und Hals. But for larger body areas, after using 6mm oder 9mm Patronen, you can use 4.5, 3.0 Und 1.5 mm cartridge for consolidation
Q: What is the difference between FL and SD cartridges?
A:
FL -Patronen Only HIFU.
SD cartridges = HIFU+RF, designed for a gentler treatment experience. You can use it for more clients with the SD cartridges.
Q: Can I use RF only function with the SD cartridges?
A:
NEIN. This device is HIFU based, so you can’t use RF only.
Q: How do I connect the handpiece and install the cartridge?
A:
Simply insert the cartridge into the handpiece slot until you hear a click. The system will confirm recognition on-screen.
Q: What should I do if the cartridge is not recognized?
A:
Überprüfen:
- Sticker is intact and clean
- Cartridge is inserted fully
- Restart the system
- If still unrecognized, contact support.
Q: How can I check the remaining shots of the cartridge?
A:
Der touchscreen displays the total remaining shots for each cartridge when installed.
Q: What happens when the cartridge reaches 0 Schüsse?
A:
There won’t be energy when the cartridges reach o shots. A new cartridge must be installed.
Q: Where can I purchase replacement cartridges and consumables?
A:
Replacement cartridges can be purchased directly from Fotromed. Contact your sales manager for support.
Start-up & Grundlegende Bedienung
Q: What should I do if the machine cannot start or has no energy output?
A: Check power connections, ensure the cartridge is properly installed, and restart the system. If the issue persists, contact technical support.
A full list of contraindications and a consent form are provided during pre-treatment.
Q: How do I set the basic parameters (Energie, pitch, length)?
Energie = strength of ultrasound pulses
Pitch = distance between each line shot
Länge = total length of treatment line
Your training guide includes safe ranges for each area.
We always recommend to start from low energy and do a patch test on the treated area.
Q: Which coupling gel should be applied before treatment?
A:
Verwenden ultrasound gel/cooling gel only. Do not substitute with other gels, as they may block ultrasound transmission.
Q: What do the “Pitch” and “Length” settings control?
A:
Pitch = space between focal points (in mm)
Länge = total treatment line length (in mm)
We don’t change the settings of pitch and length.
Q: Can the number of shots be preset?
A:
Ja. You can set a target number of shots for each session, and the system will stop once that number is reached.
Vor- & Nachbehandlungsrichtlinien
Q: Welche Vorbereitungen sind vor der Behandlung erforderlich??
A:
Remove all makeup, creams, or lotions
Cleanse and dry the treatment area
Apply ultrasound gel before treatment
Ensure client has no contraindications
Q: What is the aftercare plan following treatment?
A:
Apply one piece of medical grade mask right after the treatment to reduce redness or swelling. Cooling effect will be better if the mask is put into the fridge before the treatment.
Vermeiden Sie Sonneneinstrahlung, Saunen, or hot baths for 24–48 hours
Use gentle skincare and apply sunscreen daily
Hydrate well to support collagen renewal
Q: Who should avoid HIFU treatments?
A: Clients who are pregnant, breastfeeding, have open wounds, Schwere Akne, metal implants in the treatment area, or serious medical conditions (z.B., Epilepsie, Schrittmacher).
Q: What clinical results can clients expect?
A: Results vary, but most clients notice initial tightening immediately and progressive lifting over 2–3 months as collagen rebuilds.
Q: When can the final results be seen?
A: Full results are typically visible at 3 Monate, with improvements continuing up to 6 Monate.
Q: Is redness or numbness normal after treatment?
A: Ja. Mild redness, Schwellung, or tingling are normal and temporary. They usually resolve within hours to a few days.
Q: Can you recommend any post-treatment skincare products?
A:Ja. Fotromed offers medical grade post-treatment skincare products including spray, Serum, SPF43+ physical sunscreen, cream and mask.
Behandlung
Q: Was sind die Behandlungsschritte??
A:
Remove jewelry → Clean skin → Mark treatment lines → Apply coupling gel → Set parameters → Perform test shot → Determine client’s tolerance → Begin HIFU procedure → Wipe gel → Post-treatment care.
Q: Which areas should be avoided?
A: There have different forbidden area for different depths. The basic logic is to avoid nervy and bony area.
Q: Why should treatment avoid bony areas?
A:
Increased pain or discomfort – bone conducts ultrasound differently, so the patient may feel sharp or intense pain.
Higher risk of side effects – energy reflecting off bone can cause swelling, bruising, or even damage to surrounding tissue.
Unnecessary energy waste – since there isn’t much soft tissue between skin and bone in those areas, the energy doesn’t work effectively on collagen stimulation.
Q: What is the correct treatment order for the face (4.5mm → 3.0mm → 1.5mm)?
A: The correct order of HIFU face treatment is 5mm → 3.0mm → 1.5mm.
Q: Why must treatment proceed from deep to superficial layers?
A:
Präzision & Sicherheit
If you treat the superficial layer first, it can cause swelling or minor edema, which changes the skin’s thickness and makes it hard to target deeper layers accurately.
Starting deep ensures that the SMAS and dermis are treated correctly before the upper layers change shape.
Layered Lifting Effect
The deepest layer (SMAS, ~4.5 mm) provides the structural lift.
The middle dermal layer (3.0 mm) stimulates collagen for firmness.
The superficial layer (1.5 mm) improves skin texture and fine lines.
Doing it in order ensures the lift starts from the foundation upward, like building a house from the ground floor up.
Q: How many shots are recommended for each treatment area?
A:
Full face treatment with 3 verschiedene Tiefen: 350-550Schüsse
Neck with 3 Tiefe:100-200Schüsse
Arms 300-600shots depends on the size
Thighs 400-700shots depends on the size
Belly 300-600shots depends on the size
Q: How do I adjust the energy on the handpiece?
A:
Touchable screen, change the parameter with the machine screen at the same time.
Q: How do I perform a test shot?
A:
Please perform a test shot at the edge of the cheek, use a low setting.
Q: What is the recommended starting test energy?
A:
For face, 0.8J to 1.0J is a recommended test energy.
For Body, 1.2J to 1.5J is a recommended test energy
Q: What application technique should be used: stamping or sliding?
A:
For first learners, stamping technique is recommended. That way is making sure the energy fully cover the treatment area.
For who have experience and want to save treating time, they could use sliding mode.
Q: How many passes are recommended per area?
A:
For stamping technique, 1 pass is enough. For sliding technique, 2 passes is better.
Q: How can I ensure full coverage?
A:
We recommend you do marking on client’s face before the treatment.
Q: How do I operate with a round cartridge?
A:
With the round cartridge, you can use circling technique.
Q: What is the recommended treatment frequency?
A:
Recommended frequency: once every 3–6 months. Results usually peak after 2–3 months and last 12–18 months.
Q: During HIFU treatment, can serum replace the cooling gel?
A:
NEIN, the gel cannot replace to the cooling gel
- Ultrasound Energy Conduction
- The gel acts as a medium between the cartridge and the skin.
- Ohne es, air gaps can block or scatter the ultrasound waves, reducing penetration and making treatment less effective.
- Skin Protection & Komfort
- The gel helps absorb surface heat and prevents burns or discomfort.
- It allows the handpiece to glide smoothly across the skin.
Q: Can treatment protocols be customized for different clients?
A:
Ja, the treatment protocol can be customized. We always adjust the energy level, Patronen, and number of shots according to each client’s skin condition and treatment goals. This ensures safety, Komfort, and the best results.
Q: Was soll ich tun, wenn der Kunde keine Empfindung verspürt??
A:
Try to level up the energy if the client feels no sensation.And keep an eye of the treatment end point.
Q: What should I do if the client experiences pain?
A:
Stop the treatment immediately, and apply a medical repair mask for the client to cooling down the temperature.
Q: What are the recommended parameters for a full-face treatment?
A:
The recommended parameters for a full face is around 1.5 to 2.5J. But the most important is to see the treatment end point. There have individual difference.
Q: What are the recommended parameters for body treatments?
A:
The recommended parameters for a full face is around 2.0 to 3J. But the most important is to see the treatment end point. There have individual difference.
Q: How many sessions are needed for best results?
A:
Usually one HIFU session is enough to see lifting and tightening, with results continuing to improve over the next 2–3 months. For long-lasting effect, most clients repeat the treatment 3-4 times a year.
Q: Wie lange dauern die Ergebnisse??
A:
The results will last for 12-18 Monate.
Wartung
Q: Wie reinige ich das Handstück und die Kartuschen nach jedem Gebrauch??
A:
You can use a clean tissue or wet wipes to clean the handpiece and cartridges.
Q: Wie soll die Maschine sicher gelagert werden??
A:
The machine should be stored at a safe place, a room temperature.
Q: How often should the device undergo maintenance?
A:
Nach jeder Behandlung reinigen. Überprüfen Sie regelmäßig die Lebensdauer der Patrone, Ersetzen Sie Verbrauchsmaterialien rechtzeitig, und sorgen Sie für eine ordnungsgemäße Lagerung, um einen stabilen Betrieb aufrechtzuerhalten.
Marketingunterstützung & Zertifizierung
Q: Bieten Sie Marketingunterstützung an??
A:
Ja, Nach Abschluss unserer Schulung stellen wir Ihnen ein Schulungszertifikat aus.
Q: Legen Sie ein Schulungszertifikat vor??
A:
Ja, Nach Abschluss unserer Schulung stellen wir Ihnen ein Schulungszertifikat aus.
Q: Can the UltraLift SD be combined with other treatment programs?
A:
Ja, the UltraLift SD can be combined with other treatment, we will give you a proper suggestion with the technologies combination, includes the treatment frequency, Technologie, usw.
Spas vertrauen darauf & Kliniken weltweit
Entdecken Sie echtes Spa & Kliniken, die FotoroHIFU-Geräte verwenden. Erfahren Sie, wie Schönheitsprofis vertrauenswürdige Behandlungen verbessern, fortschrittliche HIFU-Technologie





















