UltraLift SD Compact Training FAQ

Machine Basics

Q: What is the principle of HIFU?

A:

HIFU (High-Intensity Focused Ultrasound) uses focused ultrasound energy to heat precise depths of tissue beneath the skin’s surface. It is a non-invasive cosmetic treatment that uses ultrasound energy to stimulate the deep layers of the skin, promoting collagen production and resulting in firmer, lifted skin. It is commonly used for facial tightening and body contouring.

A: Ultra SD employs Micro-Focused Ultrasound (MFU), representing an advanced iteration of HIFU technology. Key technical benefits include:

  • Enhanced targeting accuracy: Smaller focal zones allow precise energy delivery to targeted tissue layers.

  • Optimized patient comfort: Improved emission modulation ensures a more tolerable treatment experience.

  • Superior clinical outcomes: High precision enhances lifting and tightening efficacy.

  • Dual-modality synergy: Integrates HIFU with RF (Radio Frequency), compatible with sensitive skin types.

  • Ergonomically designed handpiece: Lightweight and balanced for reduced operator fatigue and improved handling.

A: The UltraLift SD Compact is designed for non-invasive face lifting, wrinkle reduction, and body contouring. It targets multiple skin layers to achieve long-lasting tightening without downtime.

A: The UltraLift SD system was launched in 2021 as an advanced version of traditional HIFU devices, offering improved precision and comfort.

A:

Compared with traditional HIFU:

More stable output for consistent results

More stable output for consistent results

Smaller, portable design (Compact version)

Enhanced cooling system for cartridge durability

Smart screen interface with pre-set modes

Upgraded SD cartridges that last longer and provide more precise energy distribution

ultralift SD Compact foldable design

Handpiece & Cartridges

Q: What do the cartridge depths (1.5mm, 3.0mm, 4.5mm) signify?

A: They represent the tissue penetration depth of ultrasound energy:

  • 1.5mm: Epidermal layer

  • 3.0mm: Dermal layer

  • 4.5mm: SMAS (superficial musculoaponeurotic system) layer

A: The stickers seal the water inlet. Water acts as a coupling medium for efficient ultrasound energy transmission.

A: Each cartridge features a visible water level indicator. Refill when the level drops below the recommended threshold.

A: Each system comes with 7 handpieces as standard. Additional handpieces can be purchased separately.

Missing items should be reported to support with a video for prompt resolution.

SD Cartridges
FL cartridges

A:

The 9mm cartridge is ideal for body tightening in areas like the abdomen, arms, thighs, and flanks. It reduces localized fat and improves skin firmness.

A:

They are primarily designed for the face and neck. But for larger body areas, after using 6mm or 9mm cartridges, you can use 4.5, 3.0 and 1.5 mm cartridge for consolidation

A:

FL cartridges Only HIFU.

SD cartridges = HIFU+RF, designed for a gentler treatment experience. You can use it for more clients with the SD cartridges.

A:

No. This device is HIFU based, so you cant use RF only.

A:

Simply insert the cartridge into the handpiece slot until you hear a click. The system will confirm recognition on-screen.

A:

Check:

  1. Sticker is intact and clean
  2. Cartridge is inserted fully
  3. Restart the system
  4. If still unrecognized, contact support.

A:

The touchscreen displays the total remaining shots for each cartridge when installed.

A:

There won’t be energy when the cartridges reach o shots. A new cartridge must be installed.

A:

Replacement cartridges can be purchased directly from Fotromed. Contact your sales manager for support.

cartridges
touch screen button

Startup & Basic Operation

Q: What should I do if the machine cannot start or has no energy output?

A: Check power connections, ensure the cartridge is properly installed, and restart the system. If the issue persists, contact technical support.

A full list of contraindications and a consent form are provided during pre-treatment.

Energy = strength of ultrasound pulses

Pitch = distance between each line shot

Length = total length of treatment line
Your training guide includes safe ranges for each area.

We always recommend to start from low energy and do a patch test on the treated area.

A:

Use ultrasound gel/cooling gel only. Do not substitute with other gels, as they may block ultrasound transmission.

80ba189a1afe77423bf9cf5033a7101c

A:

Pitch = space between focal points (in mm)

Length = total treatment line length (in mm)

We don’t change the settings of pitch and length.

A:

Yes. You can set a target number of shots for each session, and the system will stop once that number is reached.

interface

Pre- & Post-Treatment Guidelines

Q: What preparations are needed before treatment?

A:

Remove all makeup, creams, or lotions

Cleanse and dry the treatment area

Apply ultrasound gel before treatment

Ensure client has no contraindications

A:

Apply one piece of medical grade mask right after the treatment to reduce redness or swelling. Cooling effect will be better if the mask is put into the fridge before the treatment.

Avoid sun exposure, saunas, or hot baths for 24–48 hours

Use gentle skincare and apply sunscreen daily

Hydrate well to support collagen renewal

A: Clients who are pregnant, breastfeeding, have open wounds, severe acne, metal implants in the treatment area, or serious medical conditions (e.g., epilepsy, pacemaker).

A: Results vary, but most clients notice initial tightening immediately and progressive lifting over 2–3 months as collagen rebuilds.

A: Full results are typically visible at 3 months, with improvements continuing up to 6 months.

A: Yes. Mild redness, swelling, or tingling are normal and temporary. They usually resolve within hours to a few days.

A:Yes. Fotromed offers medical grade post-treatment skincare products including spray, serum, SPF43+ physical sunscreen, cream and mask.

How to Use the FotroHIFU Delux Machine (2)
Inventory Management

Treatment

Q: What are the treatment steps?

A:

Remove jewelry → Clean skin → Mark treatment lines → Apply coupling gel → Set parameters → Perform test shot → Determine client’s tolerance → Begin HIFU procedure → Wipe gel → Post-treatment care.

A: There have different forbidden area for different depths. The basic logic is to avoid nervy and bony area.

1

A:

Increased pain or discomfort – bone conducts ultrasound differently, so the patient may feel sharp or intense pain.

Higher risk of side effects – energy reflecting off bone can cause swelling, bruising, or even damage to surrounding tissue.

Unnecessary energy waste – since there isn’t much soft tissue between skin and bone in those areas, the energy doesn’t work effectively on collagen stimulation.

A: The correct order of HIFU face treatment is 5mm → 3.0mm → 1.5mm.

A:

Precision & Safety

If you treat the superficial layer first, it can cause swelling or minor edema, which changes the skin’s thickness and makes it hard to target deeper layers accurately.

Starting deep ensures that the SMAS and dermis are treated correctly before the upper layers change shape.

Layered Lifting Effect

The deepest layer (SMAS, ~4.5 mm) provides the structural lift.

The middle dermal layer (3.0 mm) stimulates collagen for firmness.

The superficial layer (1.5 mm) improves skin texture and fine lines.

Doing it in order ensures the lift starts from the foundation upward, like building a house from the ground floor up.

A:

Full face treatment with 3 different depths: 350-550shots

Neck with 3 depths:100-200shots

Arms 300-600shots depends on the size

Thighs 400-700shots depends on the size

Belly 300-600shots depends on the size

A:

Touchable screen, change the parameter with the machine screen at the same time.

d3b6d0551727c6b4cd52d06c26ee91c0

A:

Please perform a test shot at the edge of the cheek, use a low setting.

A:

For face, 0.8J to 1.0J is a recommended test energy.

For Body, 1.2J to 1.5J is a recommended test energy

A:

For first learners, stamping technique is recommended. That way is making sure the energy fully cover the treatment area.

For who have experience and want to save treating time, they could use sliding mode.

A:

For stamping technique, 1 pass is enough. For sliding technique, 2 passes is better.

A:

We recommend you do marking on client’s face before the treatment.

A:

With the round cartridge, you can use circling technique.

A:

Recommended frequency: once every 3–6 months. Results usually peak after 2–3 months and last 12–18 months.

A:

No, the gel cannot replace to the cooling gel

  • Ultrasound Energy Conduction
  • The gel acts as a medium between the cartridge and the skin.
  • Without it, air gaps can block or scatter the ultrasound waves, reducing penetration and making treatment less effective.
  • Skin Protection & Comfort
  • The gel helps absorb surface heat and prevents burns or discomfort.
  • It allows the handpiece to glide smoothly across the skin.

A:

Yes, the treatment protocol can be customized. We always adjust the energy level, cartridges, and number of shots according to each client’s skin condition and treatment goals. This ensures safety, comfort, and the best results.

A:

Try to level up the energy if the client feels no sensation.And keep an eye of the treatment end point.

A:

Stop the treatment immediately, and apply a medical repair mask for the client to cooling down the temperature.

A:

The recommended parameters for a full face is around 1.5 to 2.5J. But the most important is to see the treatment end point. There have individual difference.

A:

The recommended parameters for a full face is around 2.0 to 3J. But the most important is to see the treatment end point. There have individual difference.

A:

Usually one HIFU session is enough to see lifting and tightening, with results continuing to improve over the next 2–3 months. For long-lasting effect, most clients repeat the treatment 3-4 times a year.

A:

The results will last for 12-18 months.

feedback
1
80ba189a1afe77423bf9cf5033a7101c

Maintenance

Q: How do I clean the handpiece and cartridges after each use?

A:

You can use a clean tissue or wet wipes to clean the handpiece and cartridges.

A:

The machine should be stored at a safe place, a room temperature.

A:

Clean after every treatment. Regularly check cartridge lifespan, replace consumables on time, and ensure proper storage to maintain stable operation.

UltraLift SD Compact

Marketing Support & Certification

Q: Do you provide marketing support?

A:

Yes, we will issue you a training certificate after you finished our training.

392202543edf7de1919220190c2f5542
Q: Do you provide a training certificate?

A:

Yes, we will issue you a training certificate after you finished our training.

A:

Yes, the UltraLift SD can be combined with other treatment, we will give you a proper suggestion with the technologies combination, includes the treatment frequency, technology, etc.

17f61fdac732f34ae08a43eee9af2019

Trusted by Spas & Clinics Worldwide

Discover real spa & clinics using FotroHIFU devices. See how beauty professionals elevate treatments with trusted, advanced HIFU technology

download

Download Catalog

    By providing your mobile phone number and email address, you are agreeing to be contacted by or on behalf of the FotroMed, including emails to your email address and text messages to your mobile phone and other wireless devices.